The American Standard ACONT202AS11MA is a programmable thermostat designed for residential HVAC systems, offering precise temperature control, energy-saving scheduling, and compatibility with single-stage heating and cooling equipment. It features a backlit digital display, intuitive menu navigation, hold/vacation functions, system status indicators, and installer configuration options. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Digital display with backlight, Menu/Select buttons, Up/Down temperature adjustment, System switch (Heat/Cool/Off), Fan switch (Auto/On), Hold/Vacation buttons.
| Feature | Description |
|---|---|
| Digital Display | Backlit LCD showing temperature, time, and system status |
| Programmable Schedule | 7-day programming with 4 periods per day |
| Temperature Hold | Temporary override of programmed schedule |
| Vacation Mode | Extended energy-saving temperature setting |
| System Switch | Selects Heat, Cool, or Off mode |
| Fan Switch | Controls fan operation (Auto or Continuous On) |
| Filter Change Alert | Reminder light based on runtime hours |
| Battery Backup | Maintains program during power outages (2 AA batteries) |
| Installation Lock | Prevents unauthorized changes to installer settings |
| Compatibility | 24VAC systems; single-stage heat/cool |
Turn off power to HVAC system at circuit breaker. Remove old thermostat and label wires.
WARNING! Electrical shock hazard. Ensure power is OFF before installation. If unsure, consult a qualified HVAC technician.
After installation, configure basic settings.
CAUTION! Ensure thermostat is level for accurate temperature readings. Keep away from heat sources and drafts.
Front panel: MENU, SELECT, UP/DOWN arrows, SYSTEM (Heat/Cool/Off), FAN (Auto/On), HOLD, VACATION.
Menu Navigation: Press MENU to access TIME/DAY, SCHEDULE, SETTINGS, INSTALLER CONFIG. Use arrows to navigate, SELECT to choose.
Temperature Adjustment: Press UP/DOWN arrows to set desired temperature. System Status: Icons indicate heating, cooling, fan operation. Filter Alert: Wrench icon lights when filter change is due (based on configurable runtime).
Terminals: R (24VAC power), W (Heat), Y (Cool), G (Fan), C (Common).
Tip: Take photo of old thermostat wiring before removal for reference.
Default schedule provides energy savings while maintaining comfort.
Note: Press HOLD to temporarily override schedule. Press HOLD again to resume program.
Vacation Mode: Press VACATION, set temperature for extended away periods (40°F-99°F). Adaptive Recovery: Learns system cycle time to reach set temperature by scheduled time. Temperature Limits: Prevents extreme settings in installer configuration.
Turn off power before cleaning. Use soft, dry cloth to wipe display and casing. Do not use liquids or abrasive cleaners.
CAUTION! Do not spray cleaning solutions directly on thermostat. Moisture can damage electronics.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandard.com or contact 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/batteries | Check circuit breaker; replace AA batteries; ensure C wire connected. |
| System not turning on | Settings/wiring | Verify SYSTEM set to Heat or Cool; check thermostat wiring connections. |
| Incorrect temperature | Location/calibration | Relocate away from heat sources/drafts; check temperature calibration in installer settings. |
| Schedule not following | Hold active/programming | Cancel HOLD function; verify schedule times and temperatures are programmed. |
| Short cycling | Settings/wiring | Adjust cycle rate in installer settings; check for proper wiring and system compatibility. |
Reset: Press and hold MENU and DOWN arrow for 5 seconds to restore factory defaults (except installer settings).
Service: 1-800-228-2962; www.americanstandard.com