The American Standard ACONT800 Series is a programmable thermostat designed for precise temperature control of HVAC systems. It features a backlit digital display, multiple programming schedules (7-day, 5+2-day, or non-programmable), system mode selection (Heat, Cool, Auto, Off), fan control (Auto, On), filter change reminder, and compatibility with single-stage and multi-stage systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Backlit LCD display, Menu/Select button, Up/Down arrows, System Mode button, Fan button, Hold button, Program button.
| Feature | Description |
|---|---|
| Backlit Display | Easy-to-read screen with adjustable backlight |
| Programmable Schedules | 7-day, 5+2-day, or non-programmable options |
| System Modes | Heat, Cool, Auto, Off |
| Fan Control | Auto or Continuous On |
| Filter Change Reminder | Alerts when filter needs replacement |
| Compatibility | Single-stage and multi-stage HVAC systems |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Battery Backup | Uses AA alkaline batteries (2) |
| Temperature Hold | Temporarily override schedule |
| Keypad Lock | Prevents unauthorized changes |
Turn off power to HVAC system at circuit breaker. Remove old thermostat.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After power restoration, thermostat will initialize. Follow prompts.
CAUTION! Ensure correct wire connections to prevent system damage.
Access menu via MENU/SELECT button. Navigate with Up/Down arrows.
Front Panel: SYSTEM (mode), FAN, HOLD, PROGRAM, MENU/SELECT, Up/Down arrows.
System Modes: HEAT, COOL, AUTO, OFF. Fan Modes: AUTO (cycles with system), ON (continuous). Temperature Hold: Press HOLD to override schedule temporarily. Programming: Set Wake, Leave, Return, Sleep times and temperatures. Advanced Settings: Filter reminder interval, display brightness, temperature offset, keypad lock.
Terminals: R (24V power), C (common), Y (cooling), G (fan), W (heating), O/B (heat pump reversing valve), etc.
Tip: Refer to HVAC system manual for correct terminal designations.
Supports energy-saving schedules with up to 4 periods per day.
WARNING! Do not set extreme temperatures that could damage system or pipes.
Filter Change Reminder: Set interval (30-365 days) in menu; icon appears when due. Keypad Lock: Enable in menu to prevent changes. Temperature Calibration: Adjust displayed temperature offset if needed. System Test: Run diagnostic to verify heating, cooling, and fan operation.
Turn off power before cleaning. Use soft, dry cloth to clean display and casing. Do not use liquids or abrasive cleaners.
CAUTION! Do not spray cleaners directly on thermostat. Keep away from moisture and heat sources.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-428-4328.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check circuit breaker; ensure wires connected; replace batteries. |
| System not turning on | Mode setting/wiring | Set correct mode (Heat/Cool); check wiring at thermostat and HVAC unit. |
| Incorrect temperature | Calibration/location | Adjust temperature offset; ensure thermostat not in direct sunlight or draft. |
| Schedule not following | Hold active/programming | Cancel HOLD; verify schedule times and temperatures. |
| Fan runs continuously | Fan setting | Set fan to AUTO mode; check G wire connection. |
Reset: Remove batteries and disconnect power for 30 seconds to reset.
Service: 1-800-428-4328; www.americanstandardair.com