The American Standard ACONT850AC52UA is a programmable touchscreen thermostat designed for compatibility with most single-stage and multi-stage heating and cooling systems, including heat pumps. It features a color touchscreen display, 7-day programming, adaptive recovery, smart response technology, humidity control, remote sensor compatibility, and Wi-Fi capability for remote access via the American Standard Home app. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Color touchscreen display, mounting plate, wire labels, installation guide, level.
| Feature | Description |
|---|---|
| Color Touchscreen | High-resolution, intuitive interface for easy navigation |
| 7-Day Programming | Set different schedules for each day of the week |
| Adaptive Recovery | Learns system performance to reach setpoint at scheduled time |
| Smart Response Technology | Optimizes system runtime for comfort and efficiency |
| Humidity Control | Displays indoor humidity; compatible with humidifier/dehumidifier |
| Remote Sensor Compatible | Supports up to 3 remote sensors for temperature averaging |
| Wi-Fi Connectivity | Enables remote control via smartphone app |
| Filter Change Reminder | Alerts when to replace air filter based on runtime |
| System Status | Displays current mode, setpoint, and equipment activity |
| Backlit Display | Automatically adjusts brightness based on ambient light |
Turn off power to HVAC system at circuit breaker. Remove old thermostat and label wires.
WARNING! Electrical shock hazard. Ensure power is OFF before installation. If unsure, consult a qualified HVAC technician.
After power restore, follow on-screen prompts to configure thermostat.
CAUTION! Incorrect system configuration may cause equipment damage. Refer to HVAC system manual or contact installer.
Access menus by touching the screen. Main Screen: Displays current temp, setpoint, mode, humidity, and filter status.
Touch Buttons: MODE (Heat, Cool, Auto, Off), FAN (Auto, On), MENU, HOLD, DONE.
Settings Menu: System Setup (type, stages), Preferences (temperature scale, backlight, beep), Schedules, Alerts (filter, maintenance), Wi-Fi Setup, Dealer Info. Advanced Settings: Adaptive Recovery (On/Off), Smart Response (On/Off), Remote Sensor configuration, Humidity setpoints, Equipment output test.
Enables remote control and alerts via American Standard Home app.
Tip: Ensure thermostat is within range of your Wi-Fi router. A strong signal is required for reliable connection.
Create energy-saving schedules for weekdays and weekends.
WARNING! Do not set extreme setpoints that could cause system short-cycling or excessive runtime.
Adaptive Recovery: Learns how long your system takes to reach temperature and starts early to hit setpoint exactly at scheduled time. Smart Response: Adjusts anticipator algorithms for more precise temperature control. Remote Sensors: If installed, go to MENU > Advanced Settings > Remote Sensors to select which sensor(s) to use for temperature control (e.g., average multiple rooms).
Turn off power before cleaning. Gently wipe touchscreen with soft, dry, lint-free cloth. Do not use liquids, sprays, or abrasive cleaners.
CAUTION! Never spray cleaner directly on thermostat. Moisture can damage electronics.
FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. ICES-003: Complies with Canadian ICES-003. Copyright © American Standard Heating & Air Conditioning. All rights reserved. For technical support, visit www.americanstandardair.com or contact 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank screen | No power | Check circuit breaker; ensure C-wire is connected; verify 24VAC at terminals. |
| Wi-Fi won't connect | Network/range | Ensure 2.4 GHz network; check password; move router closer; restart thermostat. |
| HVAC not turning on | Settings/wiring | Check mode (Heat/Cool); verify setpoint; ensure correct wiring configuration. |
| Incorrect temperature | Location/sensor | Relocate thermostat away from heat sources; check remote sensor configuration. |
| Schedule not following | Hold active | Check if HOLD is on; cancel hold to resume schedule. |
Reset: MENU > Preferences > Restore Factory Defaults (will erase all settings).
Service: 1-800-228-2962; www.americanstandardair.com