The American Standard AHUI2360A200U is a programmable thermostat designed for HVAC system control, featuring a digital display, multiple programming schedules, temperature hold functions, system mode selection (Heat/Cool/Auto/Off), fan control, and compatibility with various heating and cooling systems. It includes a built-in installer setup menu, filter change reminder, and battery backup. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Digital LCD display, Control buttons, Battery compartment, Wiring terminal block, Mounting plate, System mode switch.
| Feature | Description |
|---|---|
| Digital Display | Shows current temperature, time, system status, and programming |
| Programmable Schedules | 7-day programming with 4 periods per day (Wake, Leave, Return, Sleep) |
| System Modes | Heat, Cool, Auto, Off |
| Fan Control | Auto or On continuous operation |
| Temperature Hold | Temporary or Permanent hold options |
| Filter Change Reminder | Programmable alert for maintenance |
| Battery Backup | Uses 2 AA alkaline batteries for memory retention |
| Installer Setup Menu | Advanced configuration for system type and options |
| Keypad Lock | Prevents unauthorized programming changes |
| Backlight | Illuminates display when buttons are pressed |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Ensure power is OFF before handling wires. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure basic settings.
CAUTION! Incorrect wiring or settings can damage HVAC equipment. Verify all connections match system requirements.
Front Panel: LCD display, MODE button (Heat/Cool/Auto/Off), FAN button (Auto/On), UP/DOWN arrows, HOLD button, MENU button.
Basic Operation: Press MODE to select system operation. Use arrows to set temperature. Press HOLD for temporary override.
Menu Settings: Press MENU to access Time/Day, Schedule, Filter Reminder, Installer Setup, Keypad Lock.
Installer Setup: Access by holding MENU for 5 seconds. Configure system type, temperature format, cycle rate, staging, etc.
Standard terminal designations for HVAC connections.
Tip: Refer to HVAC system manual for proper terminal identification. Take picture of old thermostat wiring before removal.
Create energy-saving schedules for weekdays and weekends.
Note: Default schedule provides energy-saving temperatures. Adjust to match household routine.
Installer menu options for system optimization.
Turn off power before cleaning. Use soft, dry cloth only; no liquids or cleaners.
CAUTION! Do not spray cleaning solutions directly on thermostat. Avoid abrasive materials.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-228-4972. This product may be covered by one or more patents. See website for details.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss or dead batteries | Check circuit breaker; replace batteries; verify 24VAC at R and C terminals. |
| System not responding | Incorrect mode or wiring | Verify MODE setting; check wiring connections; ensure thermostat is not in HOLD. |
| Inaccurate temperature | Location or calibration | Relocate away from heat sources; access installer menu for temperature calibration. |
| Short cycling | Incorrect cycle rate setting | Adjust cycle rate in installer menu (recommended: 3-6 cycles per hour). |
| Filter light flashing | Filter reminder active | Change filter; reset reminder in menu. |
| Heat pump not reversing | Incorrect O/B setting | Access installer menu; change reversing valve setting to match system. |
Reset: Remove batteries for 30 seconds to reset to factory defaults (except installer settings).
Service: 1-800-228-4972; www.americanstandardair.com