The American Standard ASYSTAT606 is a programmable digital thermostat designed for residential heating and cooling systems. It features a backlit digital display, 7-day programming capability, automatic changeover between heating and cooling modes, temperature hold functions, and system status indicators. Compatible with most 24VAC single-stage HVAC systems, it provides precise temperature control and energy-saving scheduling. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Backlit LCD display, Mode buttons, Fan control, Program/Schedule buttons, Up/Down temperature arrows, Hold button, System switch.
| Feature | Description |
|---|---|
| 7-Day Programmable | Set different schedules for each day of the week |
| Automatic Changeover | Automatically switches between heating and cooling based on setpoint |
| Temperature Hold | Temporarily override programmed schedule |
| Backlit Display | Easy reading in low light conditions |
| System Status Indicators | LEDs for Heat, Cool, Fan On, and System status |
| Filter Change Reminder | Programmable alert for HVAC filter maintenance |
| Battery Backup | Maintains settings during power outages (requires 2 AA batteries) |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Compatibility | 24VAC single-stage heating and cooling systems |
| Fan Control | Auto or On settings for continuous fan operation |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation, restore power and follow initial setup.
CAUTION! Ensure proper wire connections to prevent system damage.
Front Panel: MODE button (Heat/Cool/Auto/Off), FAN button (Auto/On), HOLD button, PROGRAM button, CLOCK button, Up/Down arrows.
Display Icons: Flame (Heating), Snowflake (Cooling), Fan (Fan On), Clock, Hold, Battery Low.
Settings Menu: Access by holding PROGRAM for 3 seconds. Options include: Temperature display (°F/°C), Filter change reminder interval (30-365 days), Temperature calibration (±5°F), System test mode.
Standard terminal designations for single-stage systems:
| Terminal | Wire Color | Function |
|---|---|---|
| R | Red | 24VAC Power |
| C | Blue/Black | Common (24VAC return) |
| W | White | Heat Stage 1 |
| Y | Yellow | Cool Stage 1 |
| G | Green | Fan Relay |
| O/B | Orange | Heat Pump Reversing Valve |
Tip: Take photo of old thermostat wiring before disconnecting for reference.
Default schedule provides energy-saving temperature setbacks.
Example Schedule: Wake 6:00 AM 70°F, Leave 8:00 AM 62°F, Return 5:00 PM 68°F, Sleep 10:00 PM 62°F.
Temperature Setbacks: Program lower heating temps and higher cooling temps when away. Adaptive Recovery: Learns system recovery time to reach setpoint by scheduled time. Filter Change Reminder: Reduces energy consumption by maintaining clean filters.
Clean display with soft, dry cloth. Do not use liquids or cleaners. Replace batteries annually or when low battery icon appears. Check and replace HVAC filters as indicated by reminder.
CAUTION! Never spray cleaning fluids directly on thermostat. Turn off power before removing for cleaning.
FCC Part 15: Class B digital device compliant. UL Listed: Meets safety standards. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-228-2962. This product may be covered by one or more patents. Check local codes for installation requirements.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/batteries | Check circuit breaker; replace batteries; verify 24VAC at R & C terminals. |
| System not responding | Incorrect mode/wiring | Verify mode setting (Heat/Cool); check wiring connections; ensure power is on. |
| Temperature inaccurate | Location/calibration | Relocate away from heat sources; use temperature calibration in settings. |
| Schedule not following | Hold active/programming | Check if HOLD is on; review programmed schedule times and temperatures. |
| Fan runs continuously | Fan setting/wiring | Set FAN to AUTO; check G terminal wiring; verify fan relay operation. |
Reset: Remove batteries and disconnect from HVAC power for 30 seconds to restore factory defaults.
Service: 1-800-228-2962; www.americanstandardair.com