The American Standard ASYSTAT656 is a programmable digital thermostat designed for precise temperature control of HVAC systems. It features a backlit LCD display, 7-day programming capability, automatic changeover between heating and cooling modes, filter change reminder, system status indicators, and compatibility with most 24VAC heating and cooling systems. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Backlit LCD display, Menu/Select button, Up/Down arrows, System switch (Heat/Cool/Off/Auto), Fan switch (Auto/On), Hold button, Program button.
| Feature | Description |
|---|---|
| 7-Day Programmable | Set different schedules for each day of the week |
| Automatic Changeover | Automatically switches between heating and cooling based on setpoint |
| Backlit Display | Easy-to-read screen with adjustable backlight |
| Filter Change Reminder | Alerts when it's time to replace the HVAC filter |
| System Status Indicators | Icons for Heat, Cool, Fan On, Hold, etc. |
| Temperature Display | Shows current room temperature and setpoint |
| Battery Backup | Maintains program during power outages (2 AA batteries) |
| Compatibility | Works with most 24VAC single-stage and multi-stage systems |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Temperature Swing | Adjustable differential for precise control |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation and power restoration, follow initial setup procedure.
CAUTION! Ensure correct wiring before restoring power to prevent equipment damage.
Front panel buttons: MENU/SELECT, UP/DOWN arrows, SYSTEM (Heat/Cool/Off/Auto), FAN (Auto/On), HOLD, PROGRAM.
Menu Navigation: Press MENU to access settings: Clock, Schedule, System, Filter, Temperature Format, Temperature Swing, Backlight, Factory Reset.
Temperature Adjustment: Use UP/DOWN arrows to change setpoint. Hold Function: Press HOLD to maintain current temperature indefinitely (press again to resume schedule). Program Override: Temporary override without changing programmed schedule. System Switch: HEAT (heating only), COOL (cooling only), AUTO (automatic changeover), OFF (system off). Fan Switch: AUTO (fan runs with heating/cooling cycles), ON (continuous fan operation).
Standard terminal designations for 24VAC systems.
Tip: Take a photo of old thermostat wiring before disconnecting. Refer to wiring diagram in manual for your specific system type.
Create energy-saving schedules with 4 periods per day.
WARNING! Do not set extreme temperature differentials (more than 10°F) between periods as it may cause system strain.
Automatic Changeover: In AUTO mode, thermostat switches between heating and cooling based on setpoint. Filter Change Reminder: Programmable interval (30-365 days); reset after filter replacement. Temperature Swing: Adjust differential between 0.5°F and 3°F for finer control. Backlight Settings: Adjust duration (5-60 seconds) or set to always on. System Test: Run system test to verify proper operation of heating, cooling, and fan.
Clean with soft, dry cloth only. Do not use liquids or abrasive cleaners. Replace batteries annually or when low battery icon appears. Check and replace HVAC filter as indicated by reminder.
CAUTION! Do not spray cleaning agents directly on thermostat. Ensure power is off before cleaning around wiring.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed: Meets safety standards. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/dead batteries | Check circuit breaker; replace batteries; verify wiring at R and C terminals. |
| System not turning on | Incorrect settings/wiring | Verify SYSTEM switch setting; check wiring connections; ensure setpoint is above/below room temperature. |
| Incorrect temperature reading | Location/calibration | Relocate thermostat away from heat sources/drafts; check calibration in menu. |
| Schedule not following program | Hold active/program error | Check if HOLD is activated; review programmed schedule times and temperatures. |
| Short cycling | Temperature swing too small | Increase temperature swing setting in menu (recommended 1.5°F). |
Reset: Menu > Settings > Factory Reset to restore default settings (erases all programming).
Service: 1-800-228-2962; www.americanstandardair.com