The American Standard Enfield T373.730 is a programmable digital thermostat designed for residential heating and cooling systems. It features a backlit digital display, 7-day programming flexibility, automatic changeover between heating and cooling modes, system status indicators, and a built-in compressor protection delay. This manual covers installation, programming, operation, and troubleshooting for optimal HVAC control and energy efficiency.
Key components: Backlit LCD display, Mode button, Fan button, Up/Down arrows, Hold button, Program button.
| Feature | Description |
|---|---|
| 7-Day Programmable | Set different schedules for each day of the week |
| Automatic Changeover | Automatically switches between heating and cooling based on setpoint |
| Backlit Display | Easy-to-read screen with adjustable backlight timeout |
| System Status Icons | Indicators for Heat, Cool, Fan On/Auto, Hold, Battery |
| Compressor Protection | Built-in 5-minute delay to protect HVAC equipment |
| Temperature Display | Shows current room temperature and setpoint |
| Battery Backup | Uses 2 AA batteries to retain settings during power loss |
| Filter Change Reminder | Programmable alert to replace air filter |
| Fahrenheit/Celsius | Selectable temperature scale |
| Keypad Lock | Prevents unauthorized changes to settings |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Ensure power is OFF before handling wires. If unsure, consult a qualified HVAC technician.
After installation and power restore, configure initial settings.
NOTE: Default temperature range is 40°F to 99°F (4°C to 37°C).
Front Panel Buttons: MODE, FAN, UP arrow, DOWN arrow, HOLD, PROGRAM.
Display Icons: Flame (Heat), Snowflake (Cool), Fan (Blower), Clock (Schedule Active), Lock (Keypad Lock), Battery (Low Battery), Wrench (Filter Alert).
Basic Operation: Press MODE to cycle through OFF, HEAT, COOL, AUTO. Press FAN to toggle between AUTO and ON. Use UP/DOWN arrows to adjust temperature setpoint. Press HOLD to temporarily override programmed schedule. Press PROGRAM to view or edit schedule.
Create a 7-day schedule with up to 4 periods per day (Wake, Leave, Return, Sleep).
Tip: Copy schedule from one day to another by selecting the target day and pressing HOLD for 3 seconds.
HEAT Mode: Controls furnace or heat pump in heating operation. System runs when room temperature falls below setpoint.
COOL Mode: Controls air conditioner or heat pump in cooling operation. System runs when room temperature rises above setpoint.
AUTO Mode: Automatic changeover. Thermostat automatically selects HEAT or COOL based on setpoint and room temperature.
OFF Mode: HVAC system is off. Fan can still be operated manually.
HOLD Function: Press HOLD to maintain current setpoint indefinitely, overriding schedule. Press HOLD again to resume program.
Access installer settings by holding SET and MODE buttons for 3 seconds. Use arrows to navigate.
CAUTION! Installer settings affect system performance. Record original settings before changing.
Clean thermostat with soft, dry cloth. Do not use liquids or cleaners.
CAUTION! Turn off power before performing any maintenance on thermostat or HVAC system.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. This thermostat is designed for use with 24VAC low-voltage systems only. Installation must comply with local electrical codes. American Standard is a trademark of American Standard Companies, Inc. For technical support, visit www.americanstandard.com or contact 1-800-843-0304.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check circuit breaker; verify 24VAC at R & C terminals; replace batteries. |
| System not turning on | Incorrect mode or setpoint | Set mode to HEAT or COOL; adjust setpoint beyond room temperature. |
| Incorrect temperature reading | Location or calibration | Relocate away from heat sources; calibrate using temperature offset in settings. |
| Short cycling | CPH setting | Adjust Cycles Per Hour in installer settings (typically 3-6 CPH). |
| Fan runs continuously | Fan setting | Press FAN button to change from ON to AUTO. |
| Schedule not following | Hold active or time wrong | Press HOLD to resume schedule; verify correct time and day. |
| No heat/cool from heat pump | O/B setting reversed | In installer settings, change O/B terminal setting from O to B or vice versa. |
Factory Reset: Hold SET and DOWN arrows for 5 seconds to restore defaults (erases all programming).
Service: 1-800-843-0304; www.americanstandard.com