The American Standard ENFIELD T373.732 is a programmable thermostat designed for residential heating and cooling systems. It features a 7-day programming schedule, large backlit display, intuitive menu navigation, temperature hold functions, system status indicators, and compatibility with most 24V HVAC systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Large backlit LCD display, Menu navigation buttons, System mode selector, Fan control, Hold button, Program override.
| Feature | Description |
|---|---|
| 7-Day Programming | Set different schedules for each day of the week |
| Backlit Display | Easy reading in low light conditions |
| Temperature Hold | Override programmed schedule temporarily |
| System Status Indicators | Shows heating, cooling, or fan operation |
| Battery Backup | Maintains settings during power outages (requires 2 AA batteries) |
| Filter Change Reminder | Programmable alert for HVAC filter maintenance |
| Keypad Lock | Prevents unauthorized changes to settings |
| Compatibility | Works with most 24V heating and cooling systems |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Temperature Accuracy | ±1°F (±0.5°C) |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation and power restoration, follow initial setup procedure.
CAUTION! Ensure proper wire connections before restoring power to prevent equipment damage.
Front panel controls: MENU, UP/DOWN arrows, SYSTEM (Heat/Off/Cool), FAN (Auto/On), HOLD.
Menu Navigation: Press MENU to access settings: Clock, Schedule, System Setup, Filter Timer, Lock, Restore Defaults.
Temperature Adjustment: Use UP/DOWN arrows to set desired temperature. Schedule Programming: Access through MENU > Schedule. Set 4 periods: Wake (6 AM), Leave (8 AM), Return (6 PM), Sleep (10 PM) with different temperatures for each. Hold Function: Press HOLD to maintain current temperature until canceled. System Mode: Select HEAT, COOL, or OFF using SYSTEM button. Fan Control: Choose AUTO (fan runs with system) or ON (continuous fan operation).
Proper wiring is essential for correct operation. Match thermostat terminals to HVAC system.
Tip: Take photo of old thermostat wiring before disconnecting for reference.
Create energy-saving schedule with different temperatures for different times.
Energy Tip: Set temperatures 7-10°F lower when away or sleeping to save energy.
Adaptive Recovery: Learns how long system takes to reach temperature and starts early. Temperature Hold Override: Temporary override without changing programmed schedule. Filter Change Reminder: Reduces energy consumption by maintaining clean filters. Vacation Mode: Extended hold period for energy savings while away.
Turn off power before cleaning. Use soft, dry cloth to clean display and casing. Do not use liquids or abrasive cleaners.
CAUTION! Never spray cleaning solutions directly on thermostat. Moisture can damage electronic components.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed: Meets safety standards for thermostats. Copyright © American Standard; trademarks of American Standard Brands. For support, visit www.americanstandard.com or contact 1-800-735-4328. Disposal: Dispose of properly according to local electronic waste regulations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check circuit breaker; verify 24V at R and C terminals; replace batteries. |
| System not turning on | Incorrect wiring or settings | Verify wire connections; check SYSTEM mode (Heat/Cool); ensure temperature setpoint above/below room temperature. |
| Incorrect temperature reading | Location or calibration | Ensure thermostat not in direct sunlight or near heat sources; check calibration in advanced settings. |
| Short cycling | Settings or equipment | Adjust cycle rate in advanced settings; check HVAC equipment. |
| Fan runs continuously | Fan setting | Change FAN setting from ON to AUTO. |
| Schedule not following program | Hold active or programming error | Cancel HOLD function; verify schedule times and temperatures. |
Reset: Menu > Settings > Restore Defaults to factory reset (erases all programming).
Service: 1-800-735-4328; www.americanstandard.com