The American Standard Enfield T37373X is a programmable thermostat designed for residential heating and cooling systems. It features a 7-day programming schedule, large backlit display, intuitive navigation, system mode selection (Heat, Cool, Auto, Off), fan control (Auto, On), temperature hold functions, and filter change reminder. Compatible with most 24VAC single-stage HVAC systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Backlit LCD display, Mode button, Fan button, Up/Down arrows, Hold button, Menu/Set button, System switch (Heat/Cool/Off/Auto).
| Feature | Description |
|---|---|
| 7-Day Programmable | Set different schedules for each day of the week |
| Large Backlit Display | Easy-to-read temperature and settings |
| System Mode Selection | Heat, Cool, Auto, Off |
| Fan Control | Auto or Continuous On |
| Temperature Hold | Temporarily override programmed schedule |
| Filter Change Reminder | Alerts when to replace HVAC filter |
| Battery Backup | Maintains settings during power outage |
| Compatibility | 24VAC single-stage heating and cooling systems |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Power Source | 24VAC from HVAC system or 2 AA batteries |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Ensure power is OFF before handling wires. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure initial settings.
CAUTION! Verify system compatibility before installation to prevent equipment damage.
Front Panel: MENU/SET, MODE (System), FAN, UP/DOWN arrows, HOLD, BACKLIGHT button.
Menu Navigation: Press MENU to access: SCHEDULE, CLOCK, SETTINGS, FILTER, VACATION.
System Modes: HEAT, COOL, AUTO (automatically switches between heat and cool), OFF. Fan Modes: AUTO (runs with HVAC cycle), ON (continuous). Temperature Hold: Press HOLD to override schedule temporarily; press again to cancel. Filter Reminder: Set interval (30-365 days) in FILTER menu. Backlight: Adjusts display brightness or auto-off timer.
Ensure correct wire labeling and terminal connections.
Tip: Take a photo of old thermostat wiring before removal for reference.
Create a custom 7-day schedule for energy savings.
WARNING! Do not set extreme temperatures that could damage system or pipes in freezing conditions.
Programmable schedules reduce energy use. Adaptive Recovery: Learns system cycle time to reach setpoint by scheduled time. Filter reminder ensures efficient airflow. Vacation mode minimizes energy while away.
Turn off power before cleaning. Use soft, dry cloth to wipe display and casing. Do not use liquids or abrasive cleaners.
CAUTION! Never spray cleaner directly on thermostat. Avoid excessive moisture.
FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandard.com or contact 1-800-228-2962. Dispose of batteries properly according to local regulations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check circuit breaker; verify 24VAC at terminals; install/replace batteries. |
| System not turning on | Incorrect wiring/mode | Verify wire connections; ensure system mode is HEAT or COOL, not OFF. |
| Incorrect temperature reading | Location/calibration | Relocate away from heat sources; check calibration in SETTINGS menu. |
| Schedule not following | Hold active/program error | Cancel HOLD function; review and reprogram schedule. |
| Short cycling | Settings/wiring | Adjust cycle rate in installer settings; check low-voltage connections. |
Reset: Press and hold MENU and DOWN arrow for 5 seconds to factory reset.
Service: 1-800-228-2962; www.americanstandard.com