The American Standard GREEN TEA T010.740 is a programmable thermostat designed for efficient HVAC control. It features a user-friendly interface, 7-day programming capability, energy-saving modes, compatibility with most heating and cooling systems, and a backlit display. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Backlit LCD display, Control buttons, Battery compartment, Wiring terminal block, Mounting plate, System switch.
| Feature | Description |
|---|---|
| Backlit LCD Display | Shows temperature, time, mode, and programming status |
| 7-Day Programmable | Allows different schedules for each day of the week |
| Hold/Vacation Mode | Temporarily overrides program or sets extended away periods |
| System Switch | Selects Heat, Cool, Auto, or Off modes |
| Fan Control | Selects Auto or On for continuous fan operation |
| Battery Backup | Maintains program during power outages (uses 2 AA batteries) |
| Energy Saving Mode | Optimizes temperature settings to reduce energy consumption |
| Filter Change Reminder | Alerts when HVAC filter needs replacement |
| Temperature Override | Temporary manual adjustment without altering program |
| Keypad Lock | Prevents unauthorized changes to settings |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Ensure power is off before handling wires. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure initial settings.
CAUTION! Incorrect system configuration may cause equipment damage. Refer to HVAC system manual or contact professional.
Front Panel: MENU, UP/DOWN arrows, SYSTEM (Heat/Cool/Auto/Off), FAN (Auto/On), HOLD.
Menu Navigation: Press MENU to access: PROGRAM SCHEDULE, CLOCK SETTINGS, PREFERENCES, INSTALLER SETUP, FILTER TIMER, VACATION SETTINGS.
Temperature Adjustment: Use UP/DOWN arrows to set desired temperature. System Mode: Select HEAT, COOL, AUTO (automatically switches between heat and cool), or OFF. Fan Control: AUTO (runs only when heating/cooling) or ON (continuous operation). Hold Function: Temporarily maintains current temperature until next scheduled period. Keypad Lock: Press and hold MENU for 5 seconds to lock/unlock.
Ensure proper wire connections for system operation.
Tip: Take a photo of original thermostat wiring before disconnecting for reference.
Create custom temperature schedules for energy efficiency.
WARNING! Extreme temperature settings may cause discomfort or system strain. Recommended difference between heat and cool settings is at least 3°F.
Energy Recovery: Calculates optimal start time to reach set temperature by scheduled period. Adaptive Intelligent Recovery: Learns system performance to improve temperature timing. Filter Change Reminder: Set interval (30-365 days) for maintenance alerts. Vacation Mode: Set extended away periods with energy-saving temperatures.
Turn off power before cleaning. Use soft, dry cloth to clean display and casing. Do not use liquids, sprays, or abrasive cleaners.
CAUTION! Never spray cleaning solutions directly on thermostat. Moisture can damage electronics.
FCC Compliance: This device complies with Part 15 of FCC Rules. Operation is subject to conditions: (1) device must not cause harmful interference, (2) device must accept any interference received. UL Listed: Meets safety standards. Copyright © American Standard. For support, visit www.americanstandard.com or contact 1-800-843-0304.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/dead batteries | Check circuit breaker; replace AA batteries; ensure wires connected properly. |
| System not turning on | Incorrect mode/wiring | Verify SYSTEM set to HEAT or COOL; check wiring at thermostat and HVAC unit. |
| Incorrect temperature reading | Location/calibration | Ensure thermostat not in direct sunlight or near heat sources; check calibration in settings. |
| Schedule not following program | Hold active/battery | Cancel HOLD function; ensure batteries installed properly; reprogram schedule. |
| Short cycling | Settings/wiring | Adjust temperature differential in installer settings; check for loose wires. |
| Fan runs continuously | Fan setting | Change FAN setting from ON to AUTO; check G terminal connection. |
Reset: Menu > Preferences > Restore Factory Defaults (Note: This erases all programming).
Service: 1-800-843-0304; www.americanstandard.com