The American Standard Thermostat M968983 is a programmable digital thermostat designed for residential HVAC systems, offering precise temperature control, energy-saving scheduling, and compatibility with most heating and cooling systems. It features a backlit LCD display, intuitive menu navigation, programmable day/week schedules, temperature hold functions, system status indicators, and filter change reminders. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Backlit LCD display, Menu buttons, System switch, Fan switch, Program/Schedule buttons, Temperature adjustment buttons, Battery compartment.
| Feature | Description |
|---|---|
| LCD Display | Shows current temperature, set point, time, day, and system status |
| Programmable Schedule | 4 time periods per day, separate weekday/weekend programs |
| Temperature Hold | Temporary or permanent override of programmed schedule |
| System Switch | Selects Heat, Cool, Off, or Auto (Heat/Cool) mode |
| Fan Switch | Selects Auto or On (continuous) fan operation |
| Filter Change Reminder | Programmable alert to replace HVAC filter |
| Battery Backup | Uses 2 AA batteries to retain settings during power loss |
| Keypad Lock | Prevents unauthorized changes to settings |
| Adaptive Recovery | Learns system timing to reach set points at scheduled times |
| Compatibility | Works with most conventional and heat pump systems |
Turn off power to HVAC system at circuit breaker. Remove old thermostat and inspect wiring.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure initial settings.
CAUTION! Incorrect system configuration may cause improper operation or equipment damage.
Access menus via MENU button. Navigate with UP/DOWN arrows, select with OK.
Front Panel: LCD Display, MENU, OK, UP/DOWN arrows, SYSTEM (Heat/Cool/Off/Auto), FAN (Auto/On), HOLD, RUN PROGRAM.
Menu Structure: CLOCK SETTINGS (Time, Day), SCHEDULE PROGRAMMING (Weekday/Weekend), INSTALLATION SETTINGS (System Type, Stages, Limits), PREFERENCES (Display Contrast, Filter Timer, Keypad Lock), SYSTEM STATUS (Current Operation, Errors).
Typical terminal connections for conventional systems:
| Terminal | Wire Color | Function |
|---|---|---|
| R / Rc | Red | 24VAC Power (Cooling) |
| Rh | Red | 24VAC Power (Heating) |
| W / W1 | White | Heat Stage 1 |
| W2 | Brown/Black | Heat Stage 2 / Aux Heat |
| Y / Y1 | Yellow | Cool Stage 1 |
| Y2 | Blue | Cool Stage 2 |
| G | Green | Fan Relay |
| C | Blue/Black | Common 24VAC |
| O/B | Orange | Heat Pump Reversing Valve |
Tip: Label wires before removing old thermostat. Refer to HVAC system manual for specific wiring.
Create energy-saving schedules for weekdays and weekends.
Example Schedule: Weekday: WAKE 6:00 AM @ 68°F, LEAVE 8:00 AM @ 62°F, RETURN 6:00 PM @ 68°F, SLEEP 10:00 PM @ 65°F.
Adaptive Recovery: Calculates optimal start time to reach set point by scheduled time. Temperature Hold: Press HOLD for temporary override; press again to cancel. Vacation Mode: Set extended hold periods for energy savings while away.
Clean display with soft, dry cloth. Do not use liquids or cleaners. Replace batteries annually or when low battery icon appears. Replace HVAC filter when filter reminder activates.
CAUTION! Do not spray cleaning agents directly on thermostat. Ensure power is off before cleaning.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandard.com or contact 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss / dead batteries | Check circuit breaker; replace batteries. |
| System not turning on | Incorrect wiring / settings | Verify wiring connections; check SYSTEM mode setting. |
| Temperature inaccurate | Location / calibration | Relocate away from heat sources; check calibration in menu. |
| Schedule not following | HOLD active / program off | Cancel HOLD; ensure RUN PROGRAM is active. |
| Short cycling | Settings / equipment issue | Check cycle rate settings; consult HVAC technician. |
Reset: Press MENU > PREFERENCES > FACTORY RESET to restore defaults.
Service: 1-800-228-2962; www.americanstandard.com