American Standard Thermostat Moments R530 Manual

The American Standard Moments R530 is a programmable thermostat designed for residential heating and cooling systems. It features a user-friendly interface, 7-day programming flexibility, energy-saving settings, compatibility with most 24V HVAC systems (single-stage heat/cool, heat pump with auxiliary heat), and precise temperature control. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Wiring Configuration 7. Programming Schedule 8. Energy Saving Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Backlit LCD display, Menu/Select button, Up/Down arrows, System switch (Heat/Cool/Off/Auto), Fan switch (Auto/On), Hold button, Program button.

FeatureDescription
Backlit LCD DisplayShows current temperature, time, day, and system status
7-Day ProgrammableAllows different schedules for each day of the week
System SwitchSelects Heat, Cool, Off, or Auto mode
Fan SwitchControls fan operation (Auto or Continuous On)
Hold ButtonTemporarily overrides programmed schedule
Program ButtonAccesses and sets programming schedule
Energy Star CertifiedDesigned for energy efficiency
Filter Change AlertReminder to replace HVAC air filter
Battery BackupUses AA batteries to retain settings during power loss
CompatibilityWorks with most 24VAC heating/cooling systems

Installation

Turn off power to HVAC system at circuit breaker before installation. Remove old thermostat and label wires.

  1. Mount baseplate: Use included screws and level to secure baseplate to wall.
  2. Connect wires: Match labeled wires to corresponding terminals on baseplate (R, Rh, Rc, W, Y, G, O/B, C, etc.).
  3. Attach thermostat: Align and snap thermostat onto baseplate.
  4. Install batteries: Insert two AA alkaline batteries for backup.
  5. Restore power: Turn circuit breaker back on.

WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.

First-Time Setup

After power is restored, follow initial setup prompts on display.

  1. Set time and day: Use Up/Down arrows and Select button.
  2. Configure system type: Select conventional (gas/oil/electric) or heat pump.
  3. Set temperature limits: Define minimum heat and maximum cool settings if desired.
  4. Program schedule: Follow guided programming for Wake, Leave, Return, Sleep periods.
  5. Test operation: Run system in Heat and Cool modes to verify proper function.

CAUTION! Ensure correct wiring to prevent equipment damage.

Specifications

Controls and Settings

Access menus via Select button. Navigate with Up/Down arrows.

Front Panel: System switch, Fan switch, Hold button, Program button, Up/Down arrows, Select button.

Menu Settings: Time/Day, System Type (Conventional/Heat Pump), Temperature Limits, Filter Change Alert (30-365 days), Display Format (F/C), Program Schedule, Battery Indicator.

Override: Press Hold to maintain current temperature until next scheduled period. Press Run Program to resume schedule.

Wiring Configuration

Typical terminal designations: R/Rh/Rc (24V power), W/W1 (Heat), Y/Y1 (Cool), G (Fan), O/B (Heat Pump Reversal), C (Common), Aux/E (Auxiliary Heat).

  1. Turn off HVAC power at breaker.
  2. Label each wire from old thermostat before disconnecting.
  3. Match wires to terminals on R530 baseplate (refer to included wiring guide).
  4. For heat pumps: Connect O/B wire per system requirements (O for cooling, B for heating).
  5. Secure wires and snap thermostat onto baseplate.

Tip: Take a photo of old thermostat wiring before removal for reference.

Programming Schedule

Allows 4 time/temperature periods per day: Wake, Leave, Return, Sleep.

  1. Press Program button.
  2. Select day or group (Weekday, Weekend, Individual Days).
  3. For each period (Wake, Leave, Return, Sleep):
    • Set time using Up/Down arrows and Select.
    • Set Heat temperature for that period.
    • Set Cool temperature for that period.
  4. Repeat for all days/groups.
  5. Press Select to save and exit.

Example Schedule: Wake 6:00 AM @ 68°F Heat, Leave 8:00 AM @ 62°F Heat, Return 6:00 PM @ 70°F Heat, Sleep 10:00 PM @ 66°F Heat.

Energy Saving Features

Programmable schedules reduce energy use when away or asleep. Filter change alert maintains system efficiency. Temperature limits prevent extreme settings. Energy Star certified for verified savings.

Care & Cleaning

Turn off power before cleaning. Use soft, dry cloth to wipe display and casing. Do not use liquids or abrasive cleaners.

CAUTION! Do not spray cleaners directly on thermostat. Avoid moisture entering unit.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-228-2962. This product is Energy Star certified. Dispose of batteries properly according to local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Blank displayPower loss, dead batteriesCheck circuit breaker; replace AA batteries.
System not turning onIncorrect mode, wiringEnsure System switch is in Heat or Cool; verify wiring at thermostat and HVAC unit.
Incorrect temperatureLocation, calibrationRelocate thermostat away from heat sources/drafts; check temperature calibration in settings.
Schedule not following programHold active, programming errorPress Run Program to resume schedule; review and reprogram schedule.
Short cyclingWiring, system issuesCheck wiring connections; consult HVAC technician for system diagnosis.

Reset: Remove batteries, turn off HVAC power for 30 seconds, restore power and reinstall batteries to reset to factory defaults.

Service: 1-800-228-2962; www.americanstandardair.com