The American Standard Moments T506.740 is a programmable thermostat designed for precise temperature control of heating and cooling systems. It features a backlit digital display, 7-day programming flexibility, automatic changeover between heating and cooling modes, filter change reminder, system status indicators, and compatibility with most 24V HVAC systems. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Digital display with backlight, Program buttons, System switch, Fan switch, Temperature adjustment buttons, Battery compartment.
| Feature | Description |
|---|---|
| Backlit Display | Easy-to-read screen with adjustable backlight |
| 7-Day Programming | Set different schedules for each day of the week |
| Automatic Changeover | Automatically switches between heating and cooling |
| Filter Change Reminder | Alerts when HVAC filter needs replacement |
| Hold/Vacation Mode | Temporarily override schedule or set vacation temperatures |
| System Status Indicators | LEDs for Heating, Cooling, and Fan operation |
| Battery Backup | Maintains programming during power outages |
| Temperature Range | 40°F to 99°F (4°C to 37°C) |
| Compatibility | Works with most 24V single-stage HVAC systems |
| Mounting Plate | Includes wall plate for easy installation |
Turn off power to HVAC system before installation. Remove old thermostat if present.
WARNING! Electrical shock hazard. Always turn off power at circuit breaker before installation.
After installation, configure basic settings.
CAUTION! Ensure wires are securely connected to prevent system malfunction.
Front Panel: SYSTEM switch (HEAT/COOL/OFF/AUTO), FAN switch (AUTO/ON), Temperature buttons, SET CLOCK, PROGRAM, HOLD, FILTER RESET.
Display Indicators: HEAT/COOL/FAN LEDs, Battery icon, Filter reminder, Hold icon.
Programming: Access via PROGRAM button to set Wake, Leave, Return, Sleep times and temperatures for each day. Settings: Temperature limits (min/max), Fahrenheit/Celsius, backlight duration, filter change interval. System Test: Initiates system test sequence to verify HVAC operation.
Standard terminal designations: R (24V power), W (Heat), Y (Cool), G (Fan), C (Common), O/B (Heat pump reversing valve).
Tip: Take photo of old wiring before removal for reference.
Create custom temperature schedules for energy savings.
WARNING! Do not set extreme temperature differentials (more than 5°F) between periods.
Programmable schedules reduce energy use when away. Adaptive Recovery: Learns system cycle time to reach set temperature by scheduled time. Temperature Limits: Prevents extreme settings. Filter Reminder: Promotes system efficiency.
Clean with soft, dry cloth only. Do not use liquids or cleaners. Replace batteries annually or when low battery icon appears. Reset filter reminder after filter change by pressing FILTER RESET.
CAUTION! Do not spray cleaning agents directly on thermostat.
FCC Part 15: Class B digital device; complies with interference limits. UL Listed: Meets safety standards. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact 1-800-428-4328.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power/bad batteries | Check circuit breaker; replace batteries; verify wiring. |
| System not turning on | Incorrect mode/wiring | Set SYSTEM to HEAT or COOL; check W/Y wire connections. |
| Incorrect temperature | Location/calibration | Relocate away from heat sources; check calibration in settings. |
| Fan runs continuously | FAN switch setting | Set FAN switch to AUTO instead of ON. |
| Schedule not following | Hold mode active | Press HOLD to cancel temporary override. |
Reset: Remove batteries and disconnect from HVAC for 30 seconds to reset.
Service: 1-800-428-4328; www.americanstandardair.com