The American Standard Thermostat ONE T064.730 is a programmable digital thermostat designed for residential HVAC systems, offering precise temperature control, energy-saving programming, and compatibility with single-stage heating and cooling systems. It features a backlit digital display, intuitive menu navigation, programmable schedules (7-day), system mode selection (Heat/Cool/Auto/Off), fan control (Auto/On), and temperature hold functions. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Digital display with backlight, Control buttons (Menu, Up/Down, Hold, Fan, System), Terminal block for wiring, Battery compartment (optional backup), Wall plate.
| Feature | Description |
|---|---|
| Digital Display | Backlit LCD showing temperature, time, and system status |
| Programmable Schedule | 7-day programming with up to 4 periods per day |
| System Modes | Heat, Cool, Auto, Off |
| Fan Control | Auto (runs with HVAC) or On (continuous) |
| Temperature Hold | Temporary or permanent override of programmed schedule |
| Filter Change Reminder | User-settable reminder based on runtime |
| Battery Backup | Optional AA batteries retain settings during power loss |
| Keypad Lock | Prevents unauthorized changes |
| Temperature Display | Shows current room and setpoint temperatures |
| Installation Menu | For configuring system type and other settings |
Unpack and inspect contents. Ensure power to HVAC system is OFF at circuit breaker.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation and power restoration, follow initial setup prompts on display.
CAUTION! Incorrect system type configuration may cause improper HVAC operation. Refer to HVAC system manual if needed.
Access menus via MENU button. Front buttons: Up/Down arrows, Hold, Fan, System, Menu.
Display Icons: Heat/Cool mode indicator, Fan status, Hold, Battery, Filter reminder.
System Menu: Mode selection (Heat/Cool/Auto/Off). Fan Menu: Auto or On. Program Menu: View/edit schedule by day. Installer Menu: System type, temperature limits, display options (F/C), filter reminder interval. Hold Function: Temporary (until next programmed period) or Permanent override.
Terminal designations: R/Rc/Rh (24V power), W/W1 (Heat), Y/Y1 (Cool), G (Fan), C (Common), O/B (Heat Pump reversing valve).
Tip: Take a photo of the old thermostat wiring before disconnecting for reference.
Create energy-saving temperature schedules for weekdays and weekends.
WARNING! Extreme temperature setbacks in very cold or hot weather may cause system strain or discomfort. Use moderate setbacks.
Programmable Schedule: Reduces energy use when home is unoccupied or occupants are asleep. Adaptive Recovery: Learns how long your system takes to reach temperature and starts early to meet schedule time. Filter Change Reminder: Prompts for filter changes to maintain system efficiency.
Turn off power before cleaning. Use a soft, dry cloth to wipe display and casing. Do not use liquids or abrasive cleaners.
CAUTION! Do not spray cleaners directly on thermostat. Moisture can damage electronics.
FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandardair.com or contact customer service at 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | No power | Check circuit breaker; ensure wires are secure at R and C terminals; install batteries. |
| System not turning on | Incorrect mode, setpoint, or wiring | Verify System is in Heat or Cool mode; ensure setpoint is above/below room temp; check wiring. |
| Incorrect temperature reading | Location or calibration | Ensure thermostat is not in direct sunlight or near heat sources; check temperature calibration in Installer Menu. |
| Schedule not following program | Hold active | Check if Hold is on; press HOLD and select Run Schedule. |
| Short cycling | Temperature differential too small | In Installer Menu, increase temperature differential (swing) setting. |
Reset: Menu > Installer Menu > Reset to Factory Defaults.
Service: 1-800-228-2962; www.americanstandardair.com