The American Standard Thermostat One T064.740 is a programmable thermostat designed for residential HVAC systems, offering precise temperature control, energy-saving programming, and compatibility with most heating and cooling systems. It features a backlit digital display, intuitive menu navigation, 7-day programming flexibility, vacation hold, filter change reminder, and system status indicators. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Digital display with backlight, Menu button, Up/Down arrows, Hold button, Fan button, System button, Mode button.
| Feature | Description |
|---|---|
| Digital display | Backlit LCD showing temperature, time, and system status |
| 7-day programming | Allows different schedules for each day of the week |
| Vacation hold | Set extended away periods for energy savings |
| Filter change reminder | Alerts when HVAC filter needs replacement |
| Compatibility | Works with most 24VAC heating and cooling systems |
| Temperature range | 40°F to 99°F (4°C to 37°C) |
| Battery backup | Uses 2 AA batteries to retain settings during power loss |
| System status icons | Indicates heating, cooling, fan operation |
| Keypad lock | Prevents unauthorized changes to settings |
| Energy usage reports | Displays runtime data for heating and cooling |
Turn off power to HVAC system before installation. Remove old thermostat and label wires.
WARNING! Electrical shock hazard. Always turn off power at circuit breaker before installation.
After installation, configure basic settings.
CAUTION! Ensure proper wire connections to prevent system damage.
Access menus via MENU button. Navigation with Up/Down arrows.
Buttons: MENU (access settings), UP/DOWN (adjust temperature/navigate), HOLD (temporary temperature override), FAN (On/Auto), SYSTEM (Heat/Cool/Off/Auto), MODE (program/view schedule).
Settings Menu: TIME/DAY (set clock), TEMP FORMAT (F/C), SYSTEM TYPE (conventional/heat pump), TEMP LIMITS (min/max), FILTER TIMER (set reminder interval), KEYPAD LOCK (enable/disable), FACTORY RESET (restore defaults). Programming: Set 4 time periods (Wake, Leave, Return, Sleep) with different temperatures for each day.
Match thermostat wires to HVAC system terminals.
Tip: Take photo of old thermostat wiring before removal for reference.
Create custom temperature schedules for energy savings.
WARNING! Do not set extreme temperatures that could damage system or pipes.
Adaptive Recovery: Learns system recovery time to reach setpoint by scheduled time. Filter Change Reminder: Program interval (30-365 days) for maintenance alert. Vacation Hold: Set extended away periods with energy-saving temperatures. Energy Reports: View heating and cooling runtime data.
Clean with soft, dry cloth only. Do not use liquids or cleaners. Replace batteries annually or when low battery icon appears. Reset filter timer after changing HVAC filter.
CAUTION! Do not spray cleaning products directly on thermostat. Keep away from direct sunlight and heat sources.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed: Meets safety standards. Copyright © American Standard; trademarks of American Standard Brands. For support, visit www.americanstandard.com or contact 1-800-843-0304.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/batteries | Check circuit breaker; replace batteries; verify C wire connection. |
| System not turning on | Settings/wiring | Check SYSTEM setting (Heat/Cool); verify wire connections; check furnace filter. |
| Incorrect temperature | Location/calibration | Relocate away from heat sources; check temperature calibration in menu. |
| Short cycling | Settings | Adjust temperature differential (cycle rate) in installer settings. |
| Fan runs continuously | FAN setting | Change FAN setting from ON to AUTO; check G wire connection. |
| Heat pump not reversing | O/B setting | Configure O/B setting for heating/cooling mode in installer settings. |
Reset: Menu > Settings > Factory Reset to restore defaults.
Service: 1-800-843-0304; www.americanstandard.com