The American Standard SELECTRONIC 605XTMV is a programmable electronic thermostat designed for precise temperature control of heating and cooling systems. It features a digital display, 7-day programming capability, automatic changeover between heating and cooling modes, adjustable temperature limits, and a built-in compressor protection delay. This manual covers safety, installation, programming, operation, and troubleshooting for optimal system performance.
Key components: Digital LCD display, Program buttons, Mode selector, Fan control, Temperature adjustment buttons, Battery compartment.
| Feature | Description |
|---|---|
| Digital Display | Shows current temperature, setpoint, time, day, and system mode |
| 7-Day Programming | Allows separate schedules for weekdays and weekends |
| Automatic Changeover | Automatically switches between heating and cooling based on setpoints |
| Temperature Limits | User-adjustable minimum and maximum temperature settings |
| Compressor Protection | Built-in delay prevents short cycling of compressor |
| Battery Backup | Maintains settings during power outages (typically uses AA batteries) |
| Fan Control | Auto or On settings for continuous or automatic fan operation |
| Hold/Temporary Override | Allows temporary temperature adjustment without affecting schedule |
| Filter Change Reminder | Programmable reminder to change HVAC system filter |
| System Mode | Heat, Cool, Auto, Off |
Turn off power to HVAC system at circuit breaker before installation.
WARNING! Electrical shock hazard. Ensure power is OFF before handling wires. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure initial settings.
CAUTION! Incorrect wiring or settings can damage HVAC equipment. Verify system compatibility before installation.
Access menus via MODE, FAN, and PROGRAM buttons. Front Panel: LCD display, Up/Down temperature buttons, HOLD button.
Button Functions: MODE (Heat/Cool/Auto/Off), FAN (Auto/On), PROGRAM (enter schedule programming), TIME/DAY (set clock), HOLD (temporary override).
Settings Menu: Access by holding PROGRAM button. Options include temperature format (F/C), filter change reminder interval, compressor protection delay, temperature limits, and system reset.
Standard terminal designations: R (24V power), W (Heat), Y (Cooling), G (Fan), C (Common), O/B (Heat pump reversing valve).
Tip: Take a photo of old thermostat wiring before disconnecting for reference.
Create energy-saving schedules for weekdays and weekends.
WARNING! Do not set extreme temperature differentials (more than 2-3°F per period) to avoid system strain.
In AUTO mode, thermostat automatically selects heating or cooling based on room temperature vs. setpoints. FAN AUTO runs fan only when system is active; FAN ON runs continuously. HOLD button overrides schedule temporarily; press again to resume program. Filter reminder flashes when interval is reached; press and hold FAN for 3 seconds to reset.
Clean display with soft, dry cloth. Do not use liquids or abrasives. Replace batteries annually or when low battery icon appears. Check wiring connections periodically for corrosion or looseness.
CAUTION! Never spray cleaning agents directly on thermostat. Ensure power is off before inspecting wiring.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. Copyright © American Standard Heating & Air Conditioning. For technical support, visit www.americanstandardair.com or contact 1-800-228-2962.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/dead batteries | Check circuit breaker; replace batteries; ensure C wire connected. |
| System not turning on | Incorrect mode/wiring | Verify MODE setting (Heat/Cool); check wiring at thermostat and HVAC unit. |
| Temperature inaccurate | Location/sensor | Relocate away from heat sources/drafts; allow 5 minutes for stabilization. |
| Short cycling | Settings/compressor delay | Increase temperature differential; ensure compressor delay is enabled (default 5 min). |
| Schedule not following | Hold active/program error | Press HOLD to cancel override; reprogram schedule; ensure clock is correct. |
Reset: Hold PROGRAM and DOWN buttons for 5 seconds to restore factory defaults.
Service: 1-800-228-2962; www.americanstandardair.com