The American Standard TOWN SQUARE T555.730 is a programmable thermostat designed for residential heating and cooling systems. It features a 7-day programming schedule, large backlit display, intuitive menu navigation, temperature hold functions, system status indicators, and compatibility with most 24V HVAC systems. Below are key sections for safety, features, installation, programming, operation, and troubleshooting.
Key components: Large backlit LCD display, Menu navigation buttons, System mode switch, Fan control, Temperature hold, Program schedule buttons.
| Feature | Description |
|---|---|
| 7-Day Programming | Set different schedules for each day of the week |
| Large Backlit Display | Easy-to-read temperature and status information |
| Temperature Hold | Temporarily override programmed schedule |
| System Mode Switch | Select Heat, Cool, Auto, or Off modes |
| Fan Control | Auto or Continuous fan operation |
| Filter Change Reminder | Programmable alert for maintenance |
| Battery Backup | Maintains program during power outages |
| Temperature Limits | Set minimum and maximum temperature ranges |
| Keypad Lock | Prevents unauthorized programming changes |
| System Status Indicators | LEDs for heating, cooling, and fan operation |
Turn off power to HVAC system before installation. Remove old thermostat carefully.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation, configure basic settings for proper operation.
CAUTION! Ensure correct system type selection to prevent equipment damage.
Access functions via front panel buttons and menu system.
Front Panel: UP/DOWN temperature buttons, MENU, HOLD, FAN, SYSTEM MODE (Heat/Cool/Auto/Off).
Menu Navigation: Press MENU to access programming, installation settings, clock setup, and filter reminder. Temperature Adjustment: Use UP/DOWN buttons to set desired temperature. Hold Function: Press HOLD to temporarily override programmed schedule. System Mode: Rotate dial to select Heat, Cool, Auto, or Off. Fan Control: Press FAN to toggle between Auto and Continuous operation.
Proper wiring is essential for correct thermostat operation.
| Terminal | Wire Color | Function |
|---|---|---|
| R/Rh/Rc | Red | 24VAC Power |
| W/W1 | White | Heat Stage 1 |
| Y/Y1 | Yellow | Cool Stage 1 |
| G | Green | Fan Control |
| O/B | Orange/Blue | Heat Pump Reversing Valve |
| C | Blue/Black | Common 24VAC |
| AUX/E | Brown/Black | Auxiliary Heat/Emergency Heat |
Tip: Take photo of old thermostat wiring before disconnecting for reference.
Create energy-saving schedule for weekdays and weekends.
Energy Tip: Program lower temperatures when away or sleeping to save energy.
Temperature Hold: Temporary override without affecting programmed schedule. Adaptive Recovery: Learns how long system takes to reach temperature, starts in advance. Filter Change Reminder: Programmable alert (30-90 days) for maintenance. Vacation Hold: Set extended away period with energy-saving temperatures.
Turn off power before cleaning. Use soft, dry cloth only. Do not use liquids or cleaning sprays.
CAUTION! Never spray liquids directly on thermostat. Avoid abrasive cleaners.
FCC Part 15: Class B digital device; complies with interference limits for residential use. UL Listed: Meets safety standards for thermostats. Copyright © American Standard Heating & Air Conditioning. For support, visit www.americanstandard.com or contact 1-800-628-4515.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss/batteries | Check circuit breaker; replace AA batteries; verify wiring. |
| System not responding | Incorrect mode/wiring | Ensure SYSTEM MODE set correctly; check wiring connections. |
| Inaccurate temperature | Location/calibration | Relocate away from heat sources; check temperature calibration. |
| Short cycling | Settings/equipment | Adjust temperature differential; check HVAC equipment. |
| Program not following schedule | Hold active/clock | Cancel HOLD function; verify correct date and time. |
Reset: Remove batteries and disconnect power for 30 seconds to reset.
Service: 1-800-628-4515; www.americanstandard.com