The American Standard Town Square T555740 is a programmable thermostat designed for residential heating and cooling systems. It features a user-friendly interface, 7-day programming capability, large backlit display, automatic changeover, system status indicators, and compatibility with most 24VAC HVAC systems. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Large backlit LCD display, intuitive touchpad interface, removable programming module, system status LEDs, and mounting plate with wire terminals.
| Feature | Description |
|---|---|
| 7-Day Programming | Set different schedules for each day of the week |
| Automatic Changeover | Automatically switches between heating and cooling |
| Large Backlit Display | Easy-to-read temperature and settings |
| System Status Indicators | LEDs for Heat, Cool, and Fan operation |
| Hold/Vacation Mode | Temporary or extended temperature overrides |
| Filter Change Reminder | Programmable alert for maintenance |
| Battery Backup | Maintains settings during power outages |
| Touchpad Controls | Simple button interface for all functions |
| Temperature Limits | User-adjustable minimum and maximum settings |
| Compatibility | Works with most 24VAC heating/cooling systems |
Turn off power to HVAC system before installation. Remove old thermostat and prepare wiring.
WARNING! Electrical shock hazard. Always turn off power before installation. If unsure, consult a qualified HVAC technician.
After installation and power restoration, configure basic settings.
CAUTION! Ensure correct system type selection to prevent equipment damage.
Front panel buttons: UP/DOWN arrows, MODE, FAN, HOLD, MENU, SET CLOCK, DONE.
Display Icons: Heat/Cool mode indicators, Fan status, Hold/Vacation, Battery low, Filter reminder.
Menu Settings: System Type (Conventional/Heat Pump), Fan Control (Auto/On), Temperature Limits, Filter Timer, Clock Format, Temperature Display (°F/°C), Reset to Factory Defaults.
Standard terminal designations for HVAC system connections.
| Terminal | Wire Color | Function |
|---|---|---|
| R / Rc / Rh | Red | 24VAC Power |
| W / W1 | White | Heat Stage 1 |
| Y / Y1 | Yellow | Cool Stage 1 |
| G | Green | Fan Control |
| C | Blue/Black | Common 24VAC |
| O/B | Orange | Heat Pump Reversing Valve |
| AUX/E | Brown | Auxiliary Heat/Emergency Heat |
Tip: Refer to HVAC system manual for specific wiring requirements. Take photo of old thermostat wiring before removal.
Create custom temperature schedules for energy savings and comfort.
Energy Saving Tip: Set temperatures 7-10°F lower/heating or higher/cooling when away or sleeping.
Daily use and special function operations.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Do not use water or chemical cleaners on thermostat. Ensure power is off before battery replacement.
FCC Part 15: Class B digital device compliant. UL Listed. Meets applicable HVAC control standards. Copyright © American Standard Heating & Air Conditioning. For technical support, visit www.americanstandard.com or contact 1-800-428-4328. This product may be covered by one or more patents. Installation should comply with local building codes and regulations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Blank display | Power loss / Dead batteries | Check circuit breaker; replace AA batteries. |
| System not responding | Incorrect wiring / Mode setting | Verify wiring connections; check HEAT/COOL/AUTO mode. |
| Temperature inaccurate | Location / Calibration | Relocate away from heat sources; check calibration in menu. |
| Short cycling | Temperature differential too small | Adjust temperature differential in advanced settings. |
| Fan runs continuously | Fan setting on ON / Wiring issue | Set fan to AUTO; check G terminal connection. |
| No heat/cool | System mode / Temperature setting | Select correct mode; ensure set point differs from room temp. |
Reset: Menu > Settings > Factory Reset (erases all programming).
Service: 1-800-428-4328; www.americanstandard.com